22276
  • 22276
  • 22276
  • 22276
  • 22276
  • 22276
  • 22276
  • 22276
  • 22276
22276
22276 22276 22276 22276 22276 22276 22276 22276
Launch X431 O2-2 Oscilloscope Box - 4 Channels 100 MHz USB DC Automotive Scope

Product Code:

22276 Weight:4.9Kg

Categories: Diagnostic Tools

Price: $ 550.00

Quantity:

Buy Now
ADD TO CART
Add to Wishlist
Share this:
Product Specification
Manufacturer Launch X431
Supporting Models Launch X431 PRO3S+ ; V5.0 ; PAD V; PAD VII
Weight 4.9 Kg
Overview
Launch X431 O2-2 Oscilloscope Box - 4 Channels 100 MHz USB DC Automotive Scope
Launch O2-2 Scope Box allows the user to capture a particular waveform which makes the process 70% more dfficient as compared to other scopes. It features the ability to record and playback high-resolution waveform data for future analysis. Its ability to input names and characters directly by clicking on the virtual keyboard streamlines the process and contributes to 90% of efficiency improvement.
LAUNCH O2-2 Scope Box For Solving Complex Electrical Faults

Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detects high level faults on various electrical components, such as sensors, acturators and circuits. By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults that enable the shop and technician to enlarge their scan tool's functionality.

Integrate with X-431 series scan tools (such as X431 PRO ELITE, X431 Throttle, X431 Pad II AE, X431 Torque, X431 Turbo, X431 Pro3S+, X431 PAD V, X431 PAD VII, X431 IMMO Elite, X431 IMMO PLUS) through the O2-2 application for conclusive diagnostic results.

Highligts:

4 channels
Bandwidth 100MHz
Auto configuration
Save waveforms with one click
Cursor measurement
One-click preset waveform parameter settings
Demo mode
Online help
Waveform math operations
23 automatic measurements

Features:

1. ECU troubleshooting and Diagnostics 
2. Features the alility to record and palyback high-resolution waveform data for future analysis. One key enable function allows the suers to capture 
3. A particular waveform which makes the process 70% more efficient as compared to other scopes 
4. Access to 23 variants of automatic measurements that  are displayed on one screen for an easy switch 
5. Ability to input names and characters directly by clicking on the virtual keyboard, this operation streamlines the process and contributes to 90% efficiency 
6. Buffer memory up to 50M 
7. Use the zoom in/out feature to review precise details 
8. Customizable personal system settings that can be saved as configuration files for viewing 
9. The Self-calibration function allows optimization of the oscillosope signal path for maximum measurement accuracy 
10. Magnifies waveform math operations, such as affition, subtraction, multiplication and FFT function for high level waveform anlysis 
11. Multiple automotive tests that include circuits, sensors, actuators, ignition tests and more 
Multi language user interface 
12. USB Sunc data transfer to external devices such as laptoop, tablet, etc..

Functions:

Supports multiple vehicle preset project tests
Supports a variety of automotive preset project tests, such as circuits, sensors, actuators, ignition tests, communication tests and combination tests, and presets various parameters and specific connection methods for each test.
 
23 automatic measurement settings
23 automatic measurement settings are displayed on one screen, which is clear at a glance and can be clicked with a light touch. It supports one-click clearing, eliminating the tediousness of turning pages and searching multiple times, making automatic measurement easy to use and convenient.
 
Quick trigger source switching
Supports edge, pulse and other triggers. Simple and intuitive trigger settings and fast trigger source switching methods make the most difficult part of oscilloscope application extremely easy.
 
Quickly create waveform preset parameters with one click
When testing waveforms, you can save the existing settings on the current interface as waveform preset parameters with one click. When testing similar waveforms later, you can directly load the preset parameters without repeated settings.
 
Quickly save waveforms with one click
Quickly save the waveform currently displayed on the screen with one click and automatically save it in the specified format. It can be directly used as a reference channel waveform for display later.
 
Convenient cursor operation
Turn on the horizontal and vertical cursors with one click respectively. Each cursor can be dragged independently, and cursor tracking is also directly implemented through simple highlight touches, improving overall efficiency by more than 80%.
 
Support cursor/phase ruler changes accordingly
When the waveform is zoomed in/out, the cursor and phase scale can change accordingly, keeping the measurement range unchanged.
 
Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally
Drag horizontally or vertically with 2 points to zoom in or out the waveform horizontally or vertically.
 
Support demonstration function
Preset sine waveforms to demonstrate common functions without connecting an oscilloscope.
 
Supports waveform math operations
Supports addition, subtraction, multiplication and division calculations of two channel waveforms, in addition to fast Fourier transform.

Detailed Comparison Between Launch O2-2 Scope Box and Launch O2-1 Scope Box
 
ModelO2-1O2-2
Channel44
Bandwith100MHz100MHz
Rise Time≤3.5ns(typical)≤3.5ns
Maximum sampling rate1Gbps(for four channels)1Gbps
Input resistance1MΩ±1.5%1MΩ±1.5%
Storage depth50M10M
Number of sampling bits8bit8bit
vertical accuracy3%3%
Vertical gear5mV~10V5mV~10V
InvertingSupportSupport
Channel coupledDC, ACDC, AC
Time base gear5ns~1ks 1ns-1ks
Time base accuracy20ppm20ppm
Sampling modeNormalNormal
CANBus decodingCAN, LINCAN, LIN
Trigger typeEdge, Pulse widthEdge, Pulse width
Trigger modeNormal, Auto and Single SEQNormal, Auto and Single SEQ
Trigger couplingDC, Noise rejectionDC, Noise rejection
MathDouble wave\FFTDouble wave\FFT
DisplayYT、Zoom、RollYT、Zoom、Roll
Roll mode200ms/div~1000s/div200ms/div~1000s/div
Auto configurationSupportSupport
Auto measurement2323
CursorHorizontal cursor, Vertical cursorHorizontal cursor, Vertical cursor
Powered byUSB port, DC IN portUSB port, DC IN port
Data transmission methodUSBUSB
Vehicle configuration optionsCircuits, sensor, actuators, ignitionCircuits, sensor, actuators, ignition
Operating temperature0℃~50℃0℃~50℃
Power supply rangeUSB:5V/1A
DC:12V/24V
USB:5V/1A
DC:12V/24V
CompatibilityDifferent tablet resolutions require different APPsOne APP can be compatible with multiple tablet resolutions
Multi-touch gesturesNoSupports 2-point touch, the waveform can be zoomed in or out vertically or horizontally
Vehicle configurationNoEach test project can support online help documentation (help documentation will be compiled according to needs later)
Firmware upgradeManual upgradeSupport online upgrade
TriggerWaveform observation cannot be expanded during normal trigger waiting.Can be used normally during normal trigger waiting.
Demo functionNoYes
Split-screenNoYes
Sampling rateSingle channel 1G/s, more than 2 channels only 250M/sSingle channel 1G/s, 2 channels 500M/s, multiple channels 250M/s
Start time2-3Sabout 16s
Power consumptionabout 6Wabout 7.5W

How to Connect the Cables?
 
Different application scenarios require different connection methods (no matter which application scenario, the following connections are required):
 
First, power the oscilloscope box through the double-clip power cable: Connect one end of the double-clip power cable to the power interface of the oscilloscope box, and the other end to the vehicle battery to draw power (red is connected to the positive pole, black is connected to the negative pole).

Note: * PADVII series tablets support USB power supply.

2. Connect the Type B terminal of the USB cable to the Type B interface of the oscilloscope, and connect the other end to the USB interface of the diagnostic device.

Specification:
 
Channels4
Bandwidth100MHz
Rising Time3.5ns (typical)
Accuracy±3%
Input Impedance1M ±1.5%
Input TypeSingle-ended, BNC Connector
Input CouplingDC, AC
Overload Protection±200V on single input
Timebase Ranges1ns~1ks (1 Channel)
 1ns~1ks (2 Channels)
 1ns~1ks (4 Channels)
Vertical Resolution8bits
Buffer Memory10M (for 4 Channels)
Power InterfaceUSB port, DC IN port
Data Exchange ViaUSB
Trigger ModeNormal, Auto and Single SEQ
Advanced TriggersEdge, Pulse width

Package List:

1pc x Launch O2-2 main unit
1pc x BNC to 4mm interface test cable
1pc x Secondary ignition pickup cable
1pc x USB cable
1pc x 20:1 attenuator 
1pc x multimeter probe
1pc x Battery clips
1pc x Piercing Probe set
2pcs x crocodile clips
1pc x Independent ignition extension cable
1pc x COP independent ignition probe
Sign Up
TEL:+8617329975062   EMAIL:carkeyunlock@gmail.com

LONGHUA DISTRICT SHENZHEN CHINA(PC.518109)

Copyright ©2017~2024 China Norman Keys Auto Electronic Co.,Ltd. Locksmith tools supplier.All rights reserved.

Notice

It is recommended that visitors in the United States and Canada visit the site deployed in North America, do you jump?

×