Código del producto:
18194 Peso:1.344KgCategorías: Diagnostic Tools
Update | One year free online update |
Warranty | 1 year |
Original | Yes |
Peso | 1.344 Kg |
Automotive oscilloscope+Digital oscilloscope+DMM+AWG
Hantek has released a newly designed handheld oscilloscope,Hantek 2d82auto.The oscillosope is custom designed for automotive test purpose,and it can also works as a common oscilloscope,a waveform generator or a digital multimeter.It looks the same as Hantek 2000 series does,but it's bandwidth is raised to 80Mhz.Over 70 types of automotive diagnostic function (Ignition/Sensor/Busdetection/Performe/Starter and charging circuits etc.) are provided. Abundant accessories are attached.
It is your most cost-effective choice!
Accessories Table
Automotive Oscilloscope with over 70 vehicle diagnostic function.Comes with abundant accessories.
Automotive diagnosis functions supported
Vehicle Diagnosis | Vehicle Diagnostic Function | Ignition | Primary Ignition (Voltage) |
Primary Ignition(current) | |||
Primary Ignition(Voltage& Current) | |||
Primary Ignition (Crankshaft Senser) | |||
Primary Ignition&SecondaryIgnition | |||
Secondary | Secondary Ignition Distributor Type (Plug Lead) | ||
Secondary Ignition Distributor Type (King Lead) | |||
Secondary DIS (Positive-fired) | |||
Secondary DIS or CPC (Negative-fired)) | |||
Secondary Coil Output Diagnosis | |||
Secondary Ignition&Primary Ignition | |||
Sensors | Air Flow Meter | Air Flow Meter (Hot Wire) | |
Air Flow Meter (Air Vane) | |||
Air FlowSensor (BOSCH Diesel) | |||
Air Intake PressureSensor (BOSCH Diesel) | |||
Camshaft | Camshaft (Inductive) | ||
Camshaft (AC Excited) | |||
Camshaft (Hall Effect) | |||
Camshaft (BOSCH Common Rail Diesel) | |||
Crankshaft | Crankshaft Inductive Running | ||
Crankshaft Inductive Cranking | |||
Crankshaft Hall Effect | |||
Crankshaft Sensor &Primary Ignition | |||
Distributor | Distributor Pick-up (Hall Effect) | ||
Distributor Inductive Pick-up Cranking | |||
Distributor Inductive Pick-up Running | |||
Lambda Sensors | Lambda Sensor Titania | ||
Lambda Sensor Zirconia | |||
Lambda Sensor Zirconia Pre & Post cat | |||
Throttle Position | Throttle Position Potentiometer | ||
Throttle Position Switch | |||
Throttle Pedal Switch (Bosch Diesel) | |||
ABS Digital Speed Sensor | |||
ABS Analog Speed Sensor | |||
Coolant Temperature (5V) | |||
Coolant Temperature (GM/Vauxhall Simtec | |||
Crash Sensor | |||
MAP Analog | |||
MAP Digital | |||
Hall Effect Road Speed Sensor | |||
Accelerator Pedal (Bosch Diesel) | |||
Bus Diagnosis | CAN Bus | CAN Bus Data View | |
CAN Bus Signal Integrity | |||
CAN Bus LH Long Capture | |||
LIN Bus | LIN Bus | ||
Engine | Petrol | Single-point Injector (Voltage) | |
Single-point Injector (Current) | |||
Multi-point Injector (Voltage) | |||
Multi-point Injector (Current) | |||
Injector Voltage & Current | |||
Injector Current & Primary Ignition | |||
Diesel | Common Rail Diesel (Current) | ||
Injector Bosch CDi 3 (Current) | |||
Injector Bosch Diesel (Idling) | |||
Injector Bosch Diesel (Accelerating) | |||
| Diesel Glow Plugs | ||
Electronic Fuel Pump | |||
Carbon Canister Solenoid Valve | |||
ERG Recirculation Solenoid Valve | |||
Stepper Motor Example 1 | |||
Stepper Motor Example 2 | |||
Idle Speed Control Valve (Rotary) | |||
Idle Speed Control Valve (Electromagmetic) | |||
Throttle Servomotor (Idling) | |||
Throttle Servomotor (Accelerating) | |||
Bosch CDi3 Quantity Control Valve | |||
Bosch CDi3 Pressure Regulator Valve | |||
Variable-Speed Cooling Fan On | |||
Variable-Speed Cooling Fan Off | |||
Variable Camshaft Valve Timing | |||
Startup & Charge | Charging Circuits | Charging Circuits Current/Voltage | |
Charging Circuits Current/Voltage Starting 24V | |||
Charging Circuits Current/Voltage Idling 24V | |||
Charging Circuits Alternator AC Ripple/Diode Diagnosis | |||
| Relative Compression Petrol | ||
Relative Compression Diesel | |||
Starting Voltage Drop |
Model | Hantek2D82 auto | ||||
Oscilloscope Mode | |||||
Bandwidth | 80MHz | ||||
Channel | 2CH+DMM+AWG | ||||
Horizontal | |||||
Sample Rate Range | 250MSa/s(Single-channel), 125MSa/s(Dual-channel) | ||||
Waveform Interpolation | (sin x)/x | ||||
Record Length | Max. 6K for single-channel; 3K samples per dual-channel | ||||
SEC/DIV Range | 5ns/div~500s/div 1, 2, 5 sequence | ||||
Vertical | |||||
A/D Converter | 8-bit resolution,each channel sampled simultaneously | ||||
VOLTS/DIV Range | 10mV/div~10V/divat input BNC | ||||
Bandwidth Limit, typical | 20MHz | ||||
Low Frequency Response (-3db) | ≤10Hz at BNC | ||||
Rise Time at BNC, typical | ≤5ns | ||||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | ||||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | |||||
Acquisition | |||||
Acquisition Modes | Normal | ||||
Trigger | |||||
Type | Edge | ||||
Mode | Auto, Normal, single | ||||
Level | ±4 divisions from center of screen | ||||
Trigger Level Accuracy | 0.2div × volts/div within ±4 divisions from center of screen | ||||
Slope | Rising, Falling, Rising & Falling | ||||
Source | CH1/CH2 | ||||
Input | |||||
Coupling | DC, AC or GND | ||||
Input Impedance, | 25pF±3 pF, 1MΩ±2% | ||||
DC coupled | |||||
Probe Attenuation | 1X, 10X | ||||
Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | ||||
Maximum Input Voltage | 150VRMS | ||||
Measurement | |||||
Cursor | Voltage difference between cursors: △V |
| |||
Time difference between cursors: △T | |||||
Automatic Measurements | Frequency, Amplitude | ||||
Arbitrary Waveform Generator Mode | |||||
Waveform Frequency | Sine: 1Hz~25MHz | - | - |
| |
Square: 1Hz~10MHz | - | - | |||
Ramp: 1Hz~1MHz | - | - | |||
EXP: 1Hz~5MHz | - | - | |||
Sampling | 250MSa/s | - | - | ||
Amplitude | 2.5Vpp(50Ω) | - | - |
| |
5Vpp(High impedance) | - | - | |||
Frequency Resolution | 0.10% | - | - | ||
Channel | 1CH waveform output | - | - | ||
Waveform Depth | 512Sa | - | - | ||
Vertical Resolution | 12 bit | - | - | ||
Output Impedance | 50 Ω | - | - | ||
DMM | |||||
Maximum Resolution | 4000 Counts | ||||
DMM Testing Modes | Voltage,Current,Resistance,Capacitance,Diode &On-Off | ||||
Maximum Input Voltage | AC:600V, DC: 800V | ||||
Maximum Input Current | AC: 10A, DC:10A | ||||
Input Impedance | 10MΩ | ||||
Measurement Term | Range | Accuracy | Resolution | ||
DC Voltage | 400.00mV | ± (0.8% + 5) | 100uV |
| |
4.000V | 1mV | ||||
40.00V | 10mV | ||||
400.0V | 100mV | ||||
600.0V | ± (1% + 2) | 1V | |||
Overload protection: 400mV: 250V, other: 600Vrms. | |||||
AC Voltage | 4.000V | ± (1.2% + 5) | 1mV |
| |
40.00V | 10mV | ||||
400.0V | 100mV | ||||
600.0V | ±(1.5% + 5) | 1V | |||
Frequency: 40Hz~400Hz; | |||||
Frequency of 400V and 600V: 40Hz~100Hz | |||||
DC Current | 40.00mA | ± (1% + 2) | 10uA |
| |
200.0mA | ± (1.5% + 2) | 100uA | |||
4.000A | ± (1.8% + 2) | 1mA | |||
10.00A | ± (3% + 2) | 10mA | |||
Overload protection: | |||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | |||||
AC Current | 40.00mA | ± (1.3% + 2) | 10uA |
| |
400.0mA | ± (1.8% + 2) | 100uA | |||
4.000A | ± (2% + 3) | 1mA | |||
10.00A | ± (3% + 5) | 10mA | |||
Frequency: 40Hz~400Hz; | |||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | |||||
Resistance | 400.0Ω | ±(1% + 3) | 0.1Ω |
| |
4.000KΩ | ±(1.2% + 5) | 1Ω | |||
60.00KΩ | 10Ω | ||||
400.0KΩ | 100Ω | ||||
4.000MΩ | 1KΩ | ||||
40.00MΩ | ± (1.5%±3) | 10KΩ | |||
Overload protection: 220Vrms | |||||
Capacitance | 40.00nF | ±(3% + 5) | 10pF |
| |
400.0nF | 100pF | ||||
4.000uF | 1nF | ||||
40.00uF | 10nF | ||||
100.0uF | 100nF | ||||
Overload protection: 220Vrms | |||||
Diode | 0V~2.0V | ||||
On-Off | <50Ω | ||||
General Specifications | |||||
Display | |||||
Display Type | 2.8 inch64K color TFT | ||||
Display Resolution | 320 horizontal by 240 vertical pixels | ||||
Display Contrast | Adjustable | ||||
Power Supply | |||||
Supply Voltage | 100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A | ||||
Power Consumption | <2.5W | ||||
Fuse | T, 3A | ||||
Battery | 2600mA*2 | ||||
| |||||
|
Auto test lead
pins set
big croc clip
test lead with clips
LONGHUA DISTRICT SHENZHEN CHINA(PC.518109)